Quick couplings for ultra high pressures AQx
Ultra high pressure systems requires high demands on the quality of the involved components. Therefore you should always choose REHOBOT approved accessories.
(A) Removal of nipple AAU436 gives G1/4" internal thread with 120° sealing cone.
(B) Adapter is required: AAU241, AAU242 or AAU243.
(C) Adapter is required: AAU244 or AAU245.
(1) Female thread with internal 120° sealing cone
(2) Female thread with internal 60° sealing cone
(3) Flow capacity is measured at 0.4 MPa (4 bar) pressure drop.
(4) Can be pressurized a maximum of 1000 times
Drawing
Product list
Name | Item code | Type | Gender | Max working pressure MPa | Inner thread | Outer thread | Flow capacity l/min (3) |
AQI150 | 49450 | Insert | Female | 150 | G 1/4" (1) | - | 6 |
AQU150 | 46573 | Insert | Male | 150 | (A) | G 1/4" | 6 |
AQI250 | 46574 | Insert | Female | 250 | G 1/4" (1) | (B) | 4.6 |
AQU250 | 46575 | Insert | Male | 250 | G 1/4" (1) | (B) | 4.6 |
AQI300(4) | 50843 | Insert | Female | 300 | M16x1,5(2) | (C) | 4.6 |
AQU300(4) | 50844 | Insert | Male | 300 | M16x1,5(2) | (C) | 4.6 |
Name | Item code | Type | Gender | Max working pressure psi | Inner thread | Outer thread | Flow capacity gal/min (3) |
AQI150 | 49450 | Insert | Female | 21750 | G 1/4" (1) | - | 1.6 |
AQU150 | 46573 | Insert | Male | 21750 | (A) | G 1/4" | 1.6 |
AQI250 | 46574 | Insert | Female | 36250 | G 1/4" (1) | (B) | 1.2 |
AQU250 | 46575 | Insert | Male | 36250 | G 1/4" (1) | (B) | 1.2 |
AQI300(4) | 50843 | Insert | Female | 43500 | M16x1,5(2) | (C) | 1.2 |
AQU300(4) | 50844 | Insert | Male | 43500 | M16x1,5(2) | (C) | 1.2 |